Box–Behnken experimental design and results for extraction yields.

Run Extraction Time (X1) (min) Ultrasonic Temperature (X2) (°C) Ultrasonic Power (X3) (W) Extraction Yield (%)
Actual Value Predicted Value
1 50.00 80.00 220.00 11.93 11.80
2 50.00 70.00 180.00 11.26 11.48
3 40.00 70.00 220.00 12.77 12.61
4 40.00 80.00 180.00 9.44 9.34
5 40.00 60.00 260.00 9.03 9.13
6 40.00 70.00 220.00 12.59 12.61
7 40.00 70.00 220.00 12.88 12.61
8 40.00 80.00 260.00 11.82 11.81
9 30.00 70.00 260.00 10.91 10.69
10 50.00 70.00 260.00 11.96 12.09
11 50.00 60.00 220.00 11.14 10.91
12 30.00 60.00 220.00 6.13 6.25
13 30.00 80.00 220.00 10.09 10.32
14 30.00 70.00 180.00 6.89 6.76
15 40.00 70.00 220.00 12.36 12.61
16 40.00 70.00 220.00 12.43 12.61
17 40.00 60.00 180.00 7.05 7.06