Continuous glucose monitoring parameters during the 72-h fast

Mean blood glucose, mg/dL 84 ± 4.3
Maximum, mg/dL 118 ± 7.5
Minimum, mg/dL 51 ± 5.7
Time at < 70 mg/dL, % 18 ± 5.8
Time at < 54 mg/dL, % 3.5 ± 1.8

Data are mean ± SE or %