Skip to main content
. Author manuscript; available in PMC: 2019 Mar 1.
Published in final edited form as: Otolaryngol Head Neck Surg. 2018 Jan 9;158(3):534–540. doi: 10.1177/0194599817751092

Table 2:

Surgical complications following transmastoid canal plugging for superior semicircular canal dehiscence

Complication Number of ears, n (%)
Prolonged disequilibrium 2 (10.5%)
New-onset sensorineural hearing loss 1 (5.3%)
New-onset tinnitus 1 (5.3%)
Wound infection 1 (5.3%)
Change in lateral canal functiona 0 (0%)
Postoperative benign positional vertigo 0 (0%)
a

Change in lateral semicircular canal function by abnormal postoperative head thrust testing.