Table 3.
Unsigned average symmetric surface distance error (UASSD) (mean ± standard deviation) in μm for intermediate AMD case. Obsv - Expert manual tracings.
Surface | Intermediate AMD | |||
---|---|---|---|---|
| ||||
OSCS vs. Obsv | CNN-S vs. Obsv | UNET-1 vs Obsv. | UNET-2 vs Obsv. | |
| ||||
S 1 | 4.52±0.74 | 4.01±0.87 | 62.34±43.79 | 45.99±35.88 |
S 2 | 9.72±1.87 | 6.36±1.97 | 18.89±3.42 | 15.63±6.84 |
S 3 | 10.30±5.33 | 5.91±1.81 | 48.09±31.36 | 29.87±15.14 |
| ||||
Overall | 8.17±2.68 | 5.43±1.68 | 42.44±26.36 | 30.49±19.51 |