Skip to main content
. 2018 Aug 29;9(9):4509–4526. doi: 10.1364/BOE.9.004509

Table 3.

Unsigned average symmetric surface distance error (UASSD) (mean ± standard deviation) in μm for intermediate AMD case. Obsv - Expert manual tracings.

Surface Intermediate AMD

OSCS vs. Obsv CNN-S vs. Obsv UNET-1 vs Obsv. UNET-2 vs Obsv.

S 1 4.52±0.74 4.01±0.87 62.34±43.79 45.99±35.88
S 2 9.72±1.87 6.36±1.97 18.89±3.42 15.63±6.84
S 3 10.30±5.33 5.91±1.81 48.09±31.36 29.87±15.14

Overall 8.17±2.68 5.43±1.68 42.44±26.36 30.49±19.51