Fig 4.

Fig 4

Correlation between attenuation and blood volume for men and women for the high pitch and AS protocol [A+B] and correlation between CNR and blood volume for men and women and the high pitch and AS protocol [C+D]. Correlation between attenuation and blood volume was slightly negative in men and women for the high pitch protocol (r = -0.296 and r = -0.033) and women for the AS protocol (r = -0.153). Men scanned with the AS protocol showed a slight positive correlation between HU and blood volume (r = 0.268) [A+B]. Correlation between CNR and blood volume was slightly negative in men for the high pitch protocol (r = -0.213) and no correlation was found between CNR and blood volume in women for the high pitch protocol. For the AS protocol, for both men and women a slight negative correlation was found (r = -0.155 and r = -0.258) [C+D]. All correlations showed no significance (p > 0.05).