Table 2b.

T1v calculated on a per-segment basis (low resolution). Intra-observer variability was based on results of scan #1 analyzed by reader #1. Inter-observer variability was based on results of scan #1 analyzed by reader #1 and reader #2. Inter-resolution variability was based on results of scan #1 analyzed by reader #1. Inter-study variability was based on results of scan #1 analyzed by reader #1 and scan #2 analyzed by reader #2

Intra-observer Inter-observer Inter-resolution Inter-study
ICC 0.974 0.859 0.711 0.594
CoV (%) 1.09 3.34 4.69 5.05
d¯ (ms) 9 20 40 52
SD 12 37 50 46
T1v threshold (ms) 33 94 140 144