Skip to main content
. 2018 Sep 25;91(13):622–624. doi: 10.1212/WNL.0000000000006251

Figure. Neurophysiologic tests.

Figure

(A) 2-Hz repetitive nerve stimulation of the nasalis muscle with 16% amplitude and 13% area decrement. (B, C) Abnormal jitter in the frontal muscle. (B) 141 μS mean consecutive difference (MCD) with blocking and (C) 205 μs MCD.