Skip to main content
. 2018 Sep 12;8(9):718. doi: 10.3390/nano8090718

Table 5.

Initial and secondary sorptivity of mortar mixes for the dry and wet-mix designs *.

Samples Initial Sorptivity (mm/s1/2) Reduction Compared to CM (%) Secondary Sorptivity (mm/s1/2) Difference with CM (%)
CM 0.007 - 0.0014 -
GMD 0.01 0.0057 −22.8 0.0013 −7.7
GMD 0.05 0.0055 −27.3 0.001 −40.0
GMD 0.1 0.0047 −48.9 0.0011 −27.3
GMD 0.5 0.0058 −20.7 0.0016 +12.5
GMD 1.0 0.0061 −14.8 0.0019 +26.3
GMW0.01 0.0054 −29.6 0.0011 −27.3
GMW0.05 0.0047 −48.9 0.0009 −55.6
GMW 0.1 0.0051 −37.3 0.001 −40.0
GMW 0.5 0.0062 −12.9 0.0012 −16.7
GMW 1.0 0.0069 −1.4 0.0016 +12.5

* (−ve means reduction, and +ve means increase compared to CM).