Skip to main content
. 2018 Sep 3;18(9):2916. doi: 10.3390/s18092916

Table 4.

The inversion results of the hybrid method and the DE inversion method for S3 and S4 in case where the parameters values are slightly outside the specified ranges. For S3 and S4, the values of ε1 and h1 exceed 5% of the specified ranges.

Parameters to Be Detected Inversion Results for Hybrid Method Estimation Errors for Hybrid Method Inversion Results for DE Method Estimation Errors for DE Method
 [ε1=3.80
 h1=2.30
 ε2=5.20]
 [ε1inv=3.80
 h1inv=2.30
 ε2inv=5.20]
 [Δε1=0.00
 Δh1=0.00
 Δε2=0.00]
 [ε1inv=4.00
 h1inv=2.18
 ε2inv=5.63]
 [Δε1=0.20
 Δh1=0.12
 Δε2=0.43]
 [ε1=4.40
 h1=1.90
 ε2=5.70]
 [ε1inv=4.40
 h1inv=1.90
 ε2inv=5.70]
 [Δε1=0.00
 Δh1=0.00
 Δε2=0.00]
 [ε1inv=4.23
 h1inv=2.00
 ε2inv=5.33]
 [Δε1=0.17
 Δh1=0.10
 Δε2=0.37]