Table 1.

Performance comparison between different algorithms and input data.

Algorithm KNN WKNN RFFP
InPut Data RSSI CSI RSSI CSI CSI
MAE in chamber (m) 1.7085 0.7608 1.1255 0.1767 0.1033
MAE in office, LOS (m) 2.8724 1.8421 2.1812 0.8164 0.1708
MAE in office, NLOS (m) 2.9463 1.7782 2.3071 1.0517 0.4033