Skip to main content
. 2018 Sep 14;18(9):3111. doi: 10.3390/s18093111

Figure 7.

Figure 7

The dynamic performance (a) and the measured response time (b) of the sensor where the V-groove pitch, depth, and angle of the sensor probe are 1 mm, 100 μm, and 60°, respectively, and the refractive index of the testing liquid is 1.39.