Table 1. Data collection, refinement and model statistics.

Deactive steady-state turnover
Data collection
Microscope

FEI Tecnai Polara

FEI Titan Krios
Camera Gatan K2 Summit Falcon III
Voltage (kV)
Nominal magnification
Calibrated pixel size (Å)
300
200,000x
1.09
300
75,000x
1.053
Total exposure (e-2) 60.5 30.7–40.7
Exposure rate (e-/pixel/s)
Number of frames
9
40
0.4
81
Defocus range (μm) 1.5–3.0 1.5–4.5
Image processing
Motion correction software

MotionCor2

MotionCor2
CTF estimation software CTFFIND4 Gctf
Particle selection software EMAN boxer and RELION2.1 RELION2.1
Initial/final micrographs 3,110/3,110 5,964/5,650
Particles selected 271,443 273,581
Applied B-factor (Å2) −142 −215
Final resolution (Å) 4.3 4.5
Refinement statistics
Modeling software

COOT, PHENIX
Number of residues 7515
Map CC (whole unit cell) 0.786
RMS deviations
Bond-lengths (Å)
0.0099
Bond-angles (°) 1.52
Av. B-factor (Å2) 151.46
Ramachandran plot
Outliers (%)

0.74
Allowed (%) 13.43
Favoured (%) 85.83
Rotamer outliers (%) 0.71
Molprobity score 2.11
All-atom clashscore 8.55
PDB ID 6GCS