Skip to main content
. 2018 Oct-Dec;30(4):216–220. doi: 10.4103/tcmj.tcmj_149_17

Table 2.

Effects of hemodialysis on hearing loss

Time of audiometric examination Patients with HL, n (%) HL in dB (mean±SD) P
Baseline 39 (66.1) 29.2±21.1 Reference
6 months 43 (72.9) 35.3±18.9 <0.001
12 months 45 (76.3) 36.9±17.3 <0.001

SD: Standard deviation, HL: Hearing loss