Skip to main content
. 2017 Sep 13;4(6):875–883. doi: 10.1002/mdc3.12536

Table 4.

Results for test‐retest and intra‐trial reliability

Experimental task Test‐retest reliability and agreementa Intra‐trial reliability and agreement: First 5 s vs. last 5 s of trial in controlsb
ICCA,1 Bias (limits of agreement) ICCA,1 Bias (limits of agreement)
Repetitive finger tapping (RFT)
Velocity (v)
v mean, cm.s−1 0.72 1.1 (−2.1, 4.3) 0.71 0.5 (−0.8, 1.9)
Δv, cm.s−2 0.17 −0.01 (−0.3, 0.3)
Frequency (f)
f mean, cycles.s−1 0.12 0.4 (−0.1, 0.8) 0.91 0.08 (−0.03, 0.19)
Δf, cycles.s−2 0.19 −0.02 (−0.05, 0.01)
Amplitude (A)
A mean, cm 0.40 −0.08 (−1.0, 0.9) 0.48 −0.02 (−0.7, 0.7)
ΔA, cm.s−1 −0.01 0.05 (−0.03, 0.12)
Interruptions of rhythm
Hesitations, no.cycle−1 0.18 −0.4 (−1.0, 0.1) 0.42 −0.04 (−0.3, 0.2)
Halts, % of time 0.90 −3.1 (−8.6, 2.3)
Alternating hand movements (AHM)
Velocity (v)
v mean, cm.s−1 0.22 −7.8 (−30.0, 14.3) 0.76 4.8 (−4.2, 13.8)
Δv, cm.s−2 0.17 −0.8 (−2.3, 0.7)
Frequency (f)
f mean, cycles.s−1 0.59 0.1 (−0.1, 0.4) 0.81 −0.004 (−0.1, 0.1)
Δf, cycles.s−2 −0.01 0.01 (−0.02, 0.04)
Amplitude (A)
A mean, cm 0.25 −4.2 (−9.8, 1.4) 0.82 −3.8 (−6.5, −1.0)
ΔA, cm.s−1 0.07 −0.02 (−0.6, 0.6)
Interruptions of rhythm
Hesitations, no.cycle−1 0.11 −0.2 (−1.0, 0.5) 0.41 −0.7 (−1.6, 0.2)
Halts, % of time 0.21 −1.1 (−3.3, 1.1) −1.6 (−3.9, 0.6)

Δ, change; ICCA,1, intraclass correlation coefficient for absolute agreement.

a

Based on N = 21 for RFT and N = 20 for AHM.

b

Based on N = 53 for RFT and AHM. Reported variables were assumed to be constant over the time course of a trial in controls. Variables Δv, Δf, and ΔA were excluded from this analysis, because the 5‐second segments were considered too short to quantify changes in velocity, frequency, and amplitude.