Table 2.
Breast | Head and Neck | Prostate | |
---|---|---|---|
Dose prescription | 2.67 Gy/fr; 15 fr | SIB: 2.12Gy/fr; 33 fr | SIB: 2.65 Gy/fr; 28 fr |
PTV: 40.05 Gy | PTV1: 54.4 Gy | PTV1: 51.8 Gy | |
PTV2: 69.96 Gy | PTV2: 65.5 Gy | ||
PTV3: 74.2 Gy | |||
2 arcs plans | |||
Number or arcs | 2 partial arcs | 2 full arcs | 2 full arcs |
Coll. angle arc 1 | (10/20)° | (10/20)° | 20° |
Coll. angle arc 2 | (350/340)° | (350/340)° | 340° |
Gantry start angle | ∼295° range: (285/307) | Full rotation | Full rotation |
Gantry stop angle | ∼173° range: (160/180) | – | – |
Avoidance sector per arc | Start: (345/20)° | – | – |
Stop (90/110)° | – | – | |
3 arcs plans (Halcyon only) | |||
Number or arcs | 3 partial arcs | 3 full arcs | 3 full arcs |
Coll. angle arc 1 | (10/20)° | (10/20)° | 20° |
Coll. angle arc 2 | (350/340)° | (350/340)° | 340° |
Coll. angle arc 3 | 90° | 90° | 90° |
Gantry start angle | ∼295°range: (285/307) | Full rotation | Full rotation |
Gantry stop angle | ∼173°range: (160/180) | – | – |
Avoidance sector per arc | Start: (345/20)° | – | – |
Stop (90/110)° | – | – |
Abbreviations: Coll., collimator; Fr, fractions; PTV, planning target volume; SIB, simultaneous integrated boost.
a The ranges expressed for the collimator rotation or in the start/stop angles for the breast and the head and neck plans represent the limits for the adjustment for individual patients.