Skip to main content
. 2018 Oct 10;13(10):e0203880. doi: 10.1371/journal.pone.0203880

Table 3. Interface circuit model parameters–non-ideal interface.

Electrode Rint .mm2) Y0,int
(×10−9)
n,int Rct
(kΩ.mm2)
Y0
(×10−9)
n Rs
.mm2)
SS—2-cell - - - 14.4
±1.0
733.0
±80.2
0.86
±0.01
202.6
±7.7
SS—3-cell - - - 14.8
±1.1
997.0
±147.9
0.84
±0.01
122.7
±9.9
Au—2-cell - - - 28.9
±5.9
1298.6
±153.2
0.80
±0.01
34.8
±1.0
Au—3-cell - - - 26.5
±1.8
1516.8
±185.5
0.79
±0.01
32.2
±1.1
AuP—2-cell - - - 3.1
±0.4
63041.7
±2667.3
0.96
±0.01
38.8
±0.3
AuP—3-cell - - - 3.3
±0.4
72525.1
±7113.2
0.96
±0.01
37.6
±0.4
EGaIn—2-cell - - - 0.8
±0.1
27091.7
±13893.0
0.79
±0.03
96.1
±13.3
EGaIn—3-cell - - - 0.9
±0.2
26134.7
±8226.9
0.79
±0.03
62.5
±5.4
SS-EGaIn—2-cell 237.9
±43.1
36190.5
±17448.7
0.70
±0.03
6.8
±1.1
6125.2
±4239.2
0.84
±0.02
252.9
±71.0
SS-EGaIn—3-cell 228.9
±31.3
74151.3
±39991.9
0.70
±0.08
5.6
±0.8
10519.1
±3621.0
0.83
±0.04
143.7
±29.1

Note: Rint, Y0,int, and nint used for SS-EGaIn electrodes only.