TABLE 1.

Reductions of three pathogens on culture media after treatment with continuous or pulsed UVC-LED irradiation at different frequencies

Microorganism Reduction (log CFU/ml)a
Continuous
1,000 Hz
20 Hz
Selective Nonselective Selective Nonselective Selective Nonselective
E. coli O157:H7 4.50 ± 0.37 A 4.94 ± 0.10 A 4.46 ± 0.16 A 5.04 ± 0.04 B 5.17 ± 0.19 A 5.10 ± 0.05 A
S. Typhimurium 2.94 ± 0.05 A 2.84 ± 0.10 A 3.43 ± 0.28 A 2.65 ± 0.43 A 4.10 ± 0.06 A 3.19 ± 0.37 B
L. monocytogenes 2.35 ± 0.30 A 1.78 ± 0.10 B 2.47 ± 0.48 A 1.77 ± 0.13 A 3.01 ± 0.59 A 2.04 ± 0.13 A
a

The highest dosages were applied (2 mJ/cm2 for E. coli O157:H7 and 5 mJ/cm2 for S. Typhimurium and L. monocytogenes). Data represent means ± standard deviations from three replications. Values followed by the same uppercase letters within rows for each treatment type are not significantly different.