Skip to main content
. 2017 Dec 26;9(1):4. doi: 10.3390/mi9010004

Table A1.

Complete data set for miniature tube type A *.

X1 X2 X3 X4 X5 Average Surface Roughness Ra (mm) Back Wall Dross responses Dbw (%)
−1 −1 −1 −1 −1 0.91 3.10
1 −1 −1 −1 −1 0.97 2.26
−1 1 −1 −1 −1 0.97 3.25
1 1 −1 −1 −1 0.99 3.73
−1 −1 1 −1 −1 0.91 3.84
1 −1 1 −1 −1 0.93 2.28
−1 1 1 −1 −1 1.05 4.72
1 1 1 −1 −1 1.07 3.55
−1 −1 −1 1 −1 0.88 5.53
1 −1 −1 1 −1 1.04 4.34
−1 1 −1 1 −1 0.98 4.92
1 1 −1 1 −1 1.15 5.60
−1 −1 1 1 −1 1.13 5.43
1 −1 1 1 −1 1.14 4.49
−1 1 1 1 −1 0.95 7.33
1 1 1 1 −1 1.36 5.85
−1 −1 −1 −1 1 1.07 3.63
1 −1 −1 −1 1 0.93 3.35
−1 1 −1 −1 1 1.06 4.55
1 1 −1 −1 1 1.24 4.73
−1 −1 1 −1 1 1.04 3.88
1 −1 1 −1 1 0.99 4.65
−1 1 1 −1 1 1.07 4.07
1 1 1 −1 1 1.28 6.69
−1 −1 −1 1 1 1.09 5.98
1 −1 −1 1 1 1.06 4.74
−1 1 −1 1 1 1.00 6.53
1 1 −1 1 1 1.14 7.24
−1 −1 1 1 1 1.19 6.97
1 −1 1 1 1 1.21 6.20
−1 1 1 1 1 1.09 6.07
1 1 1 1 1 1.37 6.85
0 0 0 0 0 1.35 5.82
0 0 0 0 0 1.32 5.53
0 0 0 0 0 1.42 6.65
0 0 0 0 0 1.41 5.59

* Miniature tube type A: X1: Pulse Frequency f (Hz); X2: Pulse Width τ (ms); X3: Peak Power Ppeak (W); X4: Cutting Speed v (mm/min); X5: Pressure P (bar).

HHS Vulnerability Disclosure