Table 1.
Uncertainty Source | Error |
---|---|
Machining error for measuring position | ±0.01 mm |
J-type thermocouple reading | ±0.15 K |
Thermal conductivity of Cu | ±2% |
Thermal conductivity of Al | ±2.1% |
Thermal contact resistance | ±2.37% |
Surface temperature reading | ±0.62% |
Heat flux | ±8.72% |
Heat transfer coefficient | ±8.74% |