Table 1.
Run | Independent variables | Response | ||
---|---|---|---|---|
Power (W) | Time (min) | Temperature (°C) | Ratio of the shear forces (%) in treated/untreated samples | |
1 | 200 (0) | 15 (+1) | 50 (+1) | 62 |
2 | 220 (+1) | 12 (0) | 30 (−1) | 47 |
3 | 220 (+1) | 9 (−1) | 40 (0) | 60 |
4 | 200 (0) | 12 (0) | 40 (0) | 43 |
5 | 200 (0) | 9 (−1) | 30 (−1) | 65 |
6 | 180 (−1) | 9 (−1) | 40 (0) | 67 |
7 | 200 (0) | 12 (0) | 40 (0) | 45 |
8 | 200 (0) | 9 (−1) | 50 (+1) | 64 |
9 | 220 (+1) | 15 (+1) | 40 (0) | 50 |
10 | 200 (0) | 12 (0) | 40 (0) | 45 |
11 | 220 (+1) | 12 (0) | 50 (+1) | 54 |
12 | 200 (0) | 15 (+1) | 30 (−1) | 57 |
13 | 180 (−1) | 15 (+1) | 40 (0) | 65 |
14 | 200 (0) | 12 (0) | 40 (0) | 44 |
15 | 180 (−1) | 12 (0) | 50 (+1) | 65 |
16 | 180 (−1) | 12 (0) | 30 (−1) | 61 |
17 | 200 (0) | 12 (0) | 40 (0) | 44 |