Model validation.

Parameter Imaging measurements (CTA, Doppler) Predictive model (pre-TMVR data) Validation model (post-TMVR data)
α angle (deg) 142 158 150
C-sept (mm) 3.1 3.6 3.7
LV AR 1.51 1.65 1.55
OF (%) 9 6.9 6.5
Mean PG LVOT (mmHg) 4 2.95 3.04
Max PG LVOT (mmHg) 5.76 6.8 5.94
Max AV velocity (m/s) 2.97 3.38 3.10

α = angle of the aorto-mitral junction at end systole. C-sept = distance between the mitral valve coaptation point and the intraventricular septum at end systole. LV AR = left ventricular aspect ratio at end systole. PG = intraventricular pressure gradients.