Skip to main content
. 2018 Oct 20;11:91. doi: 10.1186/s12920-018-0404-4

Table 4.

Software results comparison (limited gene panel)

geneCNV exomeDepth XHMM CNVkit
Subject-level sensitivity 1.0 0.875 0.75 0.5
Exon-level sensitivity 0.961 0.623 0.883 0.857
Subject-level specificity 1.0 1.0 1.0 1.0
Exon-level specificity 0.998 1.0 1.0 1.0