Skip to main content
. 2018 Oct 22;18:270. doi: 10.1186/s12886-018-0940-x

Table 2.

Measures of symmetry between right and left in 53 pair of eyes assessed with Cirrus OCT

Right eye Left eye Correlation RE-LE Interocular difference RE-LE
Mean (SD) Mean (SD) Mean difference 95% limits of agreement
Average RFNL thickness (μm) 98.7 (8.4) 98.8 (8.9) 0.881** − 0.126 −8.402–8.150
 Inferior 130.1 (15.3) 129.7 (13.6) 0.706** 0.519 − 21.45–22.49
 Superior 120.1 (14.1) 125.3 (14.7) 0.584** − 5.226 −31.05–20.6
 Nasal 75.8 (11.5) 72.9 (11.2) 0.734** 2.909 −13.39–19.21
 Temporal 68.8 (8.7) 66.5 (7.6) 0.684** 2.230 −11.36–15.82
Disc area (mm2) 1.85 (0.39) 1.90 (0.32) 0.780** − 0.044 −0.529–0.441
Rim area (mm2) 1.49 (0.26) 1.52 (0.26) 0.810** − 0.035 −0.344–0.274
Average C/D ratio 0.39 (0.16) 0.41 (0.14) 0.989** − 0.014 −0.210–0.181
Vertical C/D ratio 0.38 (0.16) 0.40 (0.13) 0.713** − 0.022 −0.242–0.197
Cup volume (mm3) 0.10 (0.10) 0.09 (0.08) 0.832** 0.005 −0.106–0.117

**p < 0.01 RE right eye, LE left eye, SD standard deviation