TABLE IV.
PRECISION, RECALL (SENSITIVITY), AND F1-SCORE FOR DIFFERENT EPOCHS FOR COMBINED (LABORATORY AND FREE-LIVING) RESULTS. ALL VALUES ARE IN PERCENT.
| Epoch (sec) | Precision (%) | Recall (%) | F1-score (%) |
|---|---|---|---|
| 3 | 87.1+/− 9.3 | 83.7 +/− 10.9 | 84.7 +/− 7.95 |
| 5 | 87.6 +/− 10.9 | 85.6 +/− 10.3 | 85.8 +/− 7.5 |
| 10 | 88.4 +/− 9.9 | 85.2 +/− 25.0 | 85.7+/− 18.7 |
| 15 | 88.1 +/− 12.7 | 81.4+/− 14.2 | 81.5+/− 11.8 |
| 20 | 88.6 +/− 16.9 | 90.1 +/− 12.4 | 87.9 +/− 13.8 |
| 25 | 85.5 +/− 12.2 | 85.4 +/− 6.0 | 82.8 +/− 8.5 |
| 30 | 84.3 +/− 12.2 | 93.3 +/− 6.0 | 87.2 +/− 8.5 |