Skip to main content
. Author manuscript; available in PMC: 2018 Nov 1.
Published in final edited form as: J Occup Environ Hyg. 2018 Aug;15(8):616–627. doi: 10.1080/15459624.2018.1479064

Table 2.

The geometric mean (GM) and geometric standard deviation (GSD) of TIL for FFP1, N95, P100, and ER respirators.

Respirator Model Aerosol TILGM GSD Min Max Filter Penetration (Aerosol Chamber) (%)*
FFP1 A NaCl 0.89 2.14 0.22 2.57 0.416 ± 0.44
Corn oil* 4.03 1.71 1.81 11.47 1.253 ± 0.87
B NaCl 18.50 2.62 4.34 69.25 0.011 ± 0.11
Corn oil 21.63 1.62 11.05 38.89 0.023 ± 0.01
N95 C NaCl 12.84 2.26 2.31 42.00 0.156 ± 0.17
Corn oil 14.20 2.24 3.45 37.04 0.347 ± 0.06
D NaCl 0.82 4.05 0.07 6.02 0.501 ± 0.95
Corn oil* 2.95 2.70 0.63 13.81 0.651 ± 1.28
P100 E NaCl 0.48 15.89 0.020 12.50 0.027 ± 0.38
Corn oil 1.19 4.48 0.08 12.08 0.069 ± 0.13
F NaCl 0.44 8.47 0.025 22.20 0.008 ± 0.0
Corn oil 0.76 24.45 0.00 16.53 0.01 ± 0.0
ER** G NaCl 0.33 4.49 0.03 2.38 0.429 ± 0.17
Corn oil 0.73 3.01 0.16 6.87 4.680 ± 0.17
H NaCl 0.19 2.83 0.06 1.05 0.147 ± 0.09
Corn oil* 1.09 1.97 0.40 4.52 2.965 ± 0.56
*

Significantly higher TIL than for NaCl aerosol.

**

ERs were used with replaceable N95 filters.