Skip to main content
. Author manuscript; available in PMC: 2019 Oct 1.
Published in final edited form as: J Mol Cell Cardiol. 2018 Sep 5;123:92–107. doi: 10.1016/j.yjmcc.2018.09.002

Table 1.

EKG intervals, Ex Vivo and In Vivo Programmed Electrical Stimulation EKG Intervals

EKG Intervals

Control Wnt LOF

Conscious HR (bpm) 692 ± 16 718 ± 12
Isoflurane HR (bpm) 488 ± 15 497 ± 23
P wave duration (msec) 12.5 ± 1.3 10.5 ± 0.7
PR (msec) 37.7 ± 0.8 34.5 ± 0.7*
QRS (msec) 10.3 ± 0.7 10.1 ± 0.4
QT (msec) 17.5 ± 0.9 17.8 ± 8

Ex Vivo Programmed Electrical Stimulation

Control Wnt LOF

Mice with VT following RV stim 0/7 5/7*
Mice with VT following LV stim 0/7 0/7
Duration VT (s) N/A 94 ± 50
VT cycle length (msec) N/A 48 ± 3
Mice with spontaneous NSVT/VT 0/7 2/7
Total episodes spontaneous NSVT/VT 0 734

In Vivo Programmed Electrical Stimulation

Control Wnt LOF
Heart Rate (bpm) 521 ± 21 572 ± 45
V to A 1:1 (msec) 90 ± 6 96 ± 6
V to A Wenckebach (msec) 83 ± 5 88 ± 5
RVERP120 (msec) 38 ± 3 28 ± 3*
Episodes NSVT/VT (S1S2) 0 10*
Total episodes NSVT/VT 0 31*