Skip to main content
. 2018 Oct 23;5:66. doi: 10.3389/fsurg.2018.00066

Table 3.

Open intraperitoneal onlay mesh with defect closure by a myoaponeurotic flap for incisional hernia repair.

Authors Study design Patients Hernia type Inclusion/Exclusion Mesh type Postoperative complications Hospital stay Recurrence
(30) Prospective observational study n = 250 Incisional 48%n re-recurrences included Dacron Mortality 0.8%, superficial wound infection 2%, deep infection 2%, mesh removal 1.2% 3.2% in a mean follow-up time of 8.1 years (range 2–14 years)
(31) Prospective observational study n = 350 Incisional 20 patients had additional surgical procedures Dacron Mortality 0.6%, wound complications 4.0% 3.1% in a mean follow-up time of 8.1 years (range 2–14 years)
(32) Prospective observational study n = 280 Incisional Parietex composite Mortality 0.35%, subcutaneous surgical site infection 2%, deep infection 2%, mesh removal 1% 3.2%