Table 4.
Open intraperitoneal onlay mesh with defect closure by sublay-technique for incisional hernia repair.
| Authors | Study design | Patients | Hernia type | Inclusion/Exclusion | Mesh type | Postoperative complications | Hospital stay | Recurrence |
|---|---|---|---|---|---|---|---|---|
| (34) | Retrospective observational study | n = 81 | Incisional | 54% had undergone prior ventral/incisional hernia repair | PTFE in 83%, Prolene in 12% | Abdominal wall abscess 12%, cellulitis without abscess 4%, hematoma 20% | Average length of stay 5.8 ± 12 days | 15% in a mean follow-up time of 30 ± 24 months |