Skip to main content
. 2018 Oct 23;5:66. doi: 10.3389/fsurg.2018.00066

Table 4.

Open intraperitoneal onlay mesh with defect closure by sublay-technique for incisional hernia repair.

Authors Study design Patients Hernia type Inclusion/Exclusion Mesh type Postoperative complications Hospital stay Recurrence
(34) Retrospective observational study n = 81 Incisional 54% had undergone prior ventral/incisional hernia repair PTFE in 83%, Prolene in 12% Abdominal wall abscess 12%, cellulitis without abscess 4%, hematoma 20% Average length of stay 5.8 ± 12 days 15% in a mean follow-up time of 30 ± 24 months
(33) Retrospective observational study n = 115 Incisional 34 recurrent hernias included ePTFE, coated polyester, coated polypropylene, biologic mesh Overall 26%, Seroma 16% 3.4% in a mean follow-up time of 363 days (range 15–2.212 days)