Skip to main content
. 2018 Jun 16;34(11):1819–1829. doi: 10.1007/s10554-018-1394-1

Table 4.

Baseline characteristics, pre- and post-procedural aortic valve characteristics on echocardiography

Mean ± SD Range
Age (years) 81 ± 5 69–88
Height (cm) 167 ± 10 144–198
Weight (kg) 74 ± 12 52–109
Pre-procedural assessment
 Ejection fraction (%) 55 ± 12 24–73
 Mean gradient (mmHg) 42 ± 17 11–77
 Maximum gradient (mmHg) 69 ± 25 21–120
 AVA (cm2) 0.82 ± 0.2 0.4–1.5
Post-procedural assessment (45) 5 ± 3 days after intervention
 Mean gradient (mmHg) 10 ± 4 4–22
 Maximum gradient (mmHg) 20 ± 8 9–45
 Aortic incompetence (AI) 1) Non/trace AI : 20 (44%)
2) Mild AI : 21 (47%)
3) Moderate AI: 4 (9%)

AI aortic incompetence, cm centimeter, cm2 square centimeter, mmHg millimeter of mercury, kg kilogram, SD standard deviation, % percent