Skip to main content
. 2016 Jun 28;8:13–29. doi: 10.2147/ORR.S35547

Table 8.

Evidence for prevalence of osteolysis and survival rate for metal-on-metal total hip replacement

Study Implant Hips (n) Mean age (years) Mean follow-up (year) Survival rate (%) Osteolysis (%)
Dastane et al141 Metasul (multicup design mated with APR stem) 30 44.7 5.5 100% at 5 years 0%
Girard et al147 Metasul Armor/Allofit cup Zweymuller SL stem/Muller cemented stem 47 (ON 54%) 25 9 94.5% at 10 years* 6% on femur
4% on pelvis
Kim et al143 CLS Metasul bearing 68 (ON 87%) 37 7 100% at 7 years 1.4% on femur
1.4% on pelvis
Park et al144 S-ROM (DePuy) 165 (ON 54%) 56.7 2.3 98.8% at 2 years 6% on femur

Note:

*

No significant differences in survival rate with different preoperative diagnoses.

Abbreviation: ON, osteonecrosis.