Skip to main content
. 2018 Sep 27;7(10):305. doi: 10.3390/jcm7100305

Table A1.

The values of area under the receiver operating characteristic curve (AUC) with 95% confidence intervals (95% CI) for single laboratory markers proposed for the early assessment of severity of acute pancreatitis that were measured in the study and compared with uPAR. We provide AUC values estimated based on results obtained on the day of admission.

Laboratory Marker AUC (95% CI); p-Value * for Prediction of
SAP Organ Failure (MMSS ≥2 Points) ICU Transfer or Death
IL-6 0.753 (0.590–0.917); p = 0.002 0.767 (0.578–0.956); p = 0.006 0.781 (0.610–0.953); p = 0.001
CRP 0.647 (0.412–0.882); p = 0.2 0.592 (0.373–0.810); p = 0.4 0.675 (0.425–0.925); p = 0.2
Procalcitonin 0.669 (0.378–0.961); p = 0.3 0.870 (0.729–1.000); p < 0.001 0.844 (0.627–1.000); p = 0.002
D-dimer 0.605 (0.377–0.901); p = 0.4 0.674 (0.485–0.863); p = 0.07 0.746 (0.582–0.909); p = 0.003
sFlt-1 0.770 (0.546–0.993); p = 0.018 0.921 (0.825–1.000); p < 0.001 0.758 (0.495–1.000); p = 0.054

* p-value in comparison with AUC = 0.5.