Skip to main content
. Author manuscript; available in PMC: 2018 Nov 1.
Published in final edited form as: Elementa (Wash D C). 2018 Jun 20;6:46. doi: 10.1525/elementa.301

Table 2:

Comparison of two combined sewer overflow (CSO) events of different magnitudes. DOI: https://doi.org/10.1525/elementa.301.t2

Event Duration (h) Volume CSO (MG)a Mean HBb (CNc 100 ml−1) Mean sewage (%)d Loade (HB CN)
19 June 2009 38.5 935.7 2.26 × 105 0.81 1.70 × 1016
20 June 2011 14.0 170.5 3.97 × 104 0.14 2.74 × 1015
a

Million gallons.

b

Mean HB (human Bacteroides) concentration at estuary station during the CSO event.

c

Copy number.

d

Computed using a geomean of 2.77 × 107 HB 100 ml−1 in untreated sewage.

e

Based on flow measurements from USGS station and 2-h concentrations of human Bacteroides (HB); loads during the CSO event are displayed and loads for full event are shown in Table 3.