Table 3. Sensitivity and specificity for metastatic lymph node detection in seven published computed tomography studies.
Study | Year | No. of patients | Detector rows × collimation (mm) | Intravenous contrast (dose) | Imaging plane | Section thickness (mm), gap (mm) | Criteria for positive LN | Interpreter(s) | Reference standard | LN number | SN (%) | SP (%) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nazim et al. (12) | 2010 | 98 | – × 0.5 | – | – | –, 0.5 | LN >1 cm | One investigator | HP report | 39 | 77 | 82 |
Türkvatan et al. (21) | 2008 | 37 | 16 × – | Iodinated contrast (320 mgI/mL) | Axial | 5, – | LN >1 cm | Two radiologists | HP report | 57 | 75 | 75 |
Kang et al. (22) | 2004 | 82 | – | – | – | –, – | LN >1 cm in short axis | – | HP report | – | 92.6 | 98.1 |
Spahn et al. (16) | 2001 | 60 | – | Yes (–) | – | 10, – | – | One radiologist | HP report | – | 100 | – |
Constantinides et al. (23) | 1991 | 47 | – | – | – | – | – | – | HP report | 27 | 60 | 85 |
Studer et al. (19) | 1990 | 163 | – | – | Axial | –, – | LN >1 cm | – | HP report | – | 78.2 | 82.1 |
Johnson et al. (20) | 1987 | 97 | – | Yes (–) | – | 10, 10 | LN >1 cm | – | HP report | – | 83 | 88 |
LN, lymph node; SN, sensitivity; SP, specificity; HP, histopathology.