Table 3.
Sample | E (MPa) | σy (MPa) | εy (%) | σb (MPa) | εb (%) |
---|---|---|---|---|---|
SA | 526 ± 52 c | 14 ± 1 d | 4 ± 1 b | 25 ± 3 cd | 30 ± 1 b |
SA0.15 | 1102 ± 68 ab | 24 ± 2 b | 3 ± 1b | 44 ± 7 ab | 24 ± 5 cd |
SA0.30 | 955 ± 74 b | 17 ± 5 c | 5 ± 2 b | 31 ± 11 c | 30 ± 3 b |
Pe | 492 ± 51 c | 13 ± 1 de | 4 ± 1 b | 21 ± 2 cd | 18 ± 2 e |
Pe0.15 | 1120 ± 112 ab | 21 ± 2 bc | 3 ± 1 b | 42 ± 5 b | 20 ± 1 de |
Pe0.30 | 1338 ± 115 a | 32 ± 5 a | 4 ± 1 b | 54 ± 7 a | 20 ± 2 de |
Pe + SA | 173 ± 17 d | 11 ± 1 e | 12 ± 1 a | 18 ± 1 d | 50 ± 1 a |
Pe + SA0.15 | 915 ± 109 b | 19 ± 3 c | 4 ± 1 b | 31 ± 4 c | 18 ± 2 e |
PE + SA0.30 | 1171 ± 98 ab | 28 ± 3 a | 4 ± 1 b | 50 ± 6 ab | 26 ± 2 bc |
Values with different letters within the same column differ significantly at p < 0.05 levels. Samples with a present the highest value, while samples with d the lowest.