Cardiac Cine-MRI Analysis of 21-Week-Old D2/mdx Mice Administered AAV-μ-Utro Compared to Vehicle Control Mice

Systolic Untreated AAV-μ-Utro
Left Ventricle

End diastolic volume (μL) 57.03 ± 3.27 46.70 ± 4.22
End systolic volume (μL) 7.43 ± 1.26 10.51 ± 1.76

Right Ventricle

End diastolic volume (μL) 53.45 ± 9.73 52.60 ± 9.06
End systolic volume (μL) 12.14 ± 2.77 17.16 ± 3.51
Stroke volume (μL) 41.32 ± 7.66 35.44 ± 6.70

Diastolic

Peak ejection rate −605.50 ± 57.60 −412.76 ± 105.32
Peak filling rate (mL/s) 474.80 ± 60.21 448.72 ± 25.59
Time to peak ejection rate (mL/s) 8.50 ± 2.35 12.33 ± 4.24