Photovoltaic parameters for PBDB-TF:IT-4F based devices with different SAs incorporated into the casting solution

Additive Mol.wt. wt.%a Voc (V) Jsc (mA cm−2) FF PCE (%)b
SA-2 234 15.6 0.87 ± 0.01 20.4 ± 0.3 0.75 ± 0.01 13.3 ± 0.2 (13.6)
SA-3 260 17.3 0.87 ± 0.01 20.3 ± 0.2 0.75 ± 0.02 13.2 ± 0.3 (13.5)
SA-4 254 16.0 0.87 ± 0.01 20.2 ± 0.2 0.75 ± 0.02 13.2 ± 0.3 (13.6)
SA-5 270 18.0 0.88 ± 0.01 20.2 ± 0.2 0.71 ± 0.01 12.6 ± 0.2 (12.9)
SA-6 276 18.4 0.88 ± 0.01 19.9 ± 0.3 0.70 ± 0.02 12.2 ± 0.3 (12.6)
SA-7 288 19.2 0.85 ± 0.01 19.8 ± 0.4 0.68 ± 0.02 11.4 ± 0.2 (11.6)
SA-8 302 20.1 0.87 ± 0.01 18.9 ± 0.4 0.56 ± 0.04 9.3 ± 0.5 (10.0)

aThe weight ratios of different additives for PBDB-TF:IT-4F-based devices were calculated from each case when the mole ratio of IT-4F: the additive was 1:1