Table 1.
Attribute | 2D Spottiswoode et al method | 3D semi-automated method |
Modality/sequence | MRI/DENSE | MRI/DENSE |
Dimension of processed data | 2D | 3D |
Primary contour detection algorithm | Phase-encoded displacements | Phase-encoded displacements |
Secondary contour detection algorithm | Modulus deformation mask | Multi-threshold based quantization |
Chamber quantifications | No direct method | EDV, ESV, EF |
Initial ROI | Bounding torus | Bounding ellipsoid |
Processing speed | 1–2 min per 2D slice | <5 min for entire LV |
Manual modification | Possible | Possible |
Strain estimations | Slice-based | Entire volume |
Surface strain maps | None | Possible |
2D, two-dimensional; 3D, three-dimensional; DENSE, Displacement Encoding with Stimulated Echoes; EDV, end-diastolic volume; EF, ejection fraction; ESV, end-systolic volume; LV, left-ventricle; ROI, region of interest.