Skip to main content
. 2018 Mar 9;91(1086):20180001. doi: 10.1259/bjr.20180001

Table 6.

Diagnostic performance for the detection of PZ prostate cancer with volume <0.5 ml stratified by presence of hemorrhage

Reader 1 Reader 2
Present hemorrhage Absent hemorrhage p value Present hemorrhage Absent hemorrhage p value
AUC 0.56 (0.44–0.68) 0.68 (0.58–0.77) 0.235 0.51 (0.39–0.63) 0.58 (0.48–0.68) 0.475
Sensitivity 0.33 (0.13–0.59) [6/18] 0.40 (0.19–0.64) [8/19] 0.663 0.06 (0.01–0.27) [1/18] 0.40 (0.19–0.64) [8/20] 0.016
Specificity 0.89 (0.78–0.96) [49/55] 0.85 (0.75–0.92) [69/81] 0.503 0.89 (0.78–0.96) [49/55] 0.79 (0.68–0.87) [63/80] 0.129
Positive predictive value 0.50 (0.27–0.73) [6/12] 0.40 (0.24–0.58) [8/20] 0.587 0.14 (0.02–0.56) [1/7] 0.32 (0.19–0.48) [8/25] 0.357
Negative predictive value 0.80 (0.74–0.85) [49/61] 0.85 (0.80–0.89) [69/80] 0.437 0.74 (0.71–0.77) [49/66] 0.84 (0.78–0.88) [63/75] 0.145

Data are 95% CI is in parentheses and numerators and denominators in brackets.