Laryngoscopy and intubation data

CL (n=40) MC (n=40) MG (n=40) CM (n=40) p
Intubation time (s) 24±8.2 26.7±8.5 12.8±7.6 20.37±9.7 <0.0001*
Intubation attempt (1/2) 34/6 35/5 35/5 35/5 0.982
Cormack–Lehane (1/2/3) 17/20/3 15/22/3 21/17/2 18/18/4 0.873
Need for stylet/manipulation 4/14 1/9 0/9 2/8 0.095
Sore throat 16 9 2 5 0.006**
*

Tukey’s post-test: MG and CM significantly shorter than CL and MC,

**

Tukey’s post-test: MG and CM significantly shorter than CL and MC. Continuous data are presented as mean ± standard deviation and categorical data as the number of cases and percentage.

CL: Macintosh direct laryngoscope-classic laryngoscope; MC: McCoy laryngoscope; MG: McGrath video-laryngoscope; CM: C-Mac video-laryngoscope