Skip to main content
. 2018 Sep 19;23(9):2399. doi: 10.3390/molecules23092399

Table 1.

Total copper concentration of cotton samples determined by inductively coupled plasma-atomic emission spectrometry a (ICP-AES).

Sample Description Digested Fabric Copper (Total) mg/L Calc. Total Copper Per Fabric (mg/g) % Add-On b
5 mM CuCl2·2H2O + 125 mM Asc. Acid 190.8 3.31 -
2 mM CuCl2·2H2O + 125 mM Asc. Acid 82.4 1.51 0.25
2 mM CuCl2·2H2O + 50 mM Na. Asc. 225.2 4.20 0.52
5 mM CuCl2·2H2O + 125 mM Na. Asc. 756 14.64 0.75
2 mM CuCl2·2H2O + 10 mM Na. Asc. 170 3.23 1.2
2 mM CuCl2·2H2O + 10 mM Asc. Acid 152.8 2.53 0.96
Cotton c control 0.52 0.01
Untreated brown cotton d 0.72 0.01

a Copper total was determined after microwave acid digestion by ICP-AES according to EPA method 200.7 and reported in mg/L; b Add-on percent calculated for samples 1–4 after rinsing fabric and 24 h equilibration; samples 5–6 add-on percent calculated after 24 h equilibration; c Untreated hydroentangled upland white cotton (unbleached); d Untreated brown cotton variety B-14.