Skip to main content
. 2018 Sep 21;6(9):e180. doi: 10.2196/mhealth.9975

Table 2.

Frequencies and percentages of evaluations given by 5 pathologists for images taken during forensic necropsies with Google Glass and Nikon D3200 reflex camera stratified for each group.

Parameters assessed and scorea Group A, n (%) Group B, n (%) Group C, n (%)


Glass (n=1800) DSLRb camera (n=1800) Glass (n=1505) DSLR camera (n=1505) Glass (n=1602) DSLR camera (n=1602)
Region of interest

5 426 (23.7) 933 (51.8) 173 (11.5) 522 (34.7) 55 (3.4) 1027 (63.4)

4 964 (53.6) 803 (44.6) 650 (43.2) 898 (59.7) 287 (17.7) 519 (32.0)

3 393 (21.8) 64 (3.6) 622 (41.3) 85 (5.6) 827(51.1) 74 (4.6)

2 17 (0.9) 0 (0) 60 (4) 0 (0) 451 (27.8) 0 (0)

1 0 (0) 0 (0) 0 (0) 0 (0) 0 (0) 0 (0)
Sharpness

5 353 (19.6) 1005 (55.8) 37 (2.5) 434 (28.8) 125 (7.7) 762 (47)

4 842 (46.8) 708 (39.4) 801 (53.2) 929 (61.7) 296(18.3) 718 (44.4)

3 580 (32.2) 87 (4.8) 597 (39.7) 142 (9.4) 735 (45.4) 140 (8.6)

2 25 (1.4) 0 (0) 70 (4.6) 0 (0) 464 (28.6) 0 (0)

1 0 (0) 0 (0) 0 (0) 0 (0) 0 (0) 0 (0)
Overall color settings

5 268 (14.9) 912 (50.7) 100 (6.6) 852 (56.6) 2 (0.1) 813 (50.2)

4 1022 (56.8) 783 (43.5) 713 (47.4) 619 (41.1) 573 (35.4) 742 (45.8)

3 507 (28.1) 105 (5.8) 582 (38.7) 34 (2.3) 770 (47.5) 65 (4.0)

2 3 (0.2) 0 (0) 110 (7.3) 0 (0) 275 (17) 0 (0)

1 0 (0) 0 (0) 0 (0) 0 (0) 0 (0) 0 (0)
Brightness

5 285 (15.8) 997 (55.4) 204 (13.6) 680 (45.2) 125 (7.7) 880 (54.3)

4 983(54.6) 688 (38.2) 786(52.2) 806(53.6) 870 (53.7) 645 (39.8)

3 482 (26.8) 115 (6.4) 494 (32.8) 19 (1.3) 513 (31.7) 95 (5.9)

2 50 (2.8) 0 (0) 21 (1.4) 0 (0) 112 (6.9) 0 (0)

1 0 (0) 0 (0) 0 (0) 0 (0) 0 (0) 0 (0)

aParameters were assessed on a scale of 1-5 (1, very poor; 2, poor; 3, average; 4, good, 5, very good).

bDSLR: digital single-lens reflex.