Levels of radon emitted from the faults in the study area in accordance with the Code for Indoor Environmental Pollution Control of Civil Building Engineering in China (GB 50325–2010)27.

Levels Radon concentration (kBq m−3) Radon flux (mBq m−2 s−1) Locations Prevention regulations
1 0~20 0~50 NCY, DHZK, YJY, YLK, ZZK,YJG, ZJY, NKC, YXZ, BKC, XHZ, DYZ, LTTC, BYC, NYC No need of pollution prevention and control of radon
2 20~30 50~100 CFY, WQX, QBK, HJP, YHM, CJA, HJW, WFS, SJC, SHZ, DTHS The underlying surface of the structure should be fixed in order to prevent cracking
3 30~50 100~300 QXZ, BHC, WZ, BHD, DSG Underlying surface of the structure should be remedied in order to prevent cracking, and water proof processing
4 >50 >300 DDG, PGZ, WJKC, ZTD, FN Comprehensive prevention and control of radon pollution