Skip to main content
. 2018 Nov 12;4(11):e00930. doi: 10.1016/j.heliyon.2018.e00930

Table 1.

Previously reported procedures for SPE of 5-Fu.

NO. Solid phase type Determination technique Medium Linearity LOD LOQ Recovery Ref.
1 OasisWax extraction cartridge LC-MS/MS human cultured cellular matrix 7.5–150 (ng/ml) - 7.5 (ng/ml) 85% (37)
3 Oasis HLB (copolymer of poly(di- vinylbenzene-co-N-vinylpyrrolidone)) cartridge column LC-MS human plasma 0.05–25 (μg/ml) - 8.4 (ng/ml) 73.1–74.8% (38)
4 Isolute ENV+ column GC–MS/MS hospital water (waste and surface water) 2-106 (ng/L) 0.48 (ng/L) for waste and 0.16 (ng/L) for surface water 1.6 (ng/L) for waste and 0.54 (ng/L) for surface water 53% for waste and 93% for surface water (39)
5 ENV+ columns Capillary electrophoresis hospital waste water samples 5–500 (μg/ml) 1.7 (μg/ml) 8.6 (μg/ml) 80–96% (40)
6 Isolute
ENV+ cartridges
GC/MS-MS hospital waste water 0.09–40 (μg/L) 12 (ng/L) 40 (ng/ml) 93–101% (41)
7 C18 Chem Elut
Cartridge
HPLC human plasma 25–1000 (ng/ml) - 20 (ng/ml) 35% (42)
8 AgNPs@MCM-41-HF capillary electrophoresis with in-column field-amplified sample injection Human plasma 25–1000 (ng/ml) - 25 (ng/ml) 98% [43]