Skip to main content
. 2018 Nov;19(11):863–870. doi: 10.1631/jzus.B1800230

Table 4.

Correlations between the corneal thickness differences, pupillary center position and TA, J 0, J 45, HOA in keratoconic patients after FBDALK (n=47)

Variable TA3 mm
J 0
J 45
HOA3 mm
HOA6 mm
r Sig. r Sig. r Sig. r Sig. r Sig.
Corneal thickness difference
 S-I2 mm 0.27 0.07 0.31 0.03* 0.42 0.00* 0.37 0.01* 0.48 0.00*
 S-I4 mm 0.25 0.09 0.21 0.15 0.28 0.06 0.30 0.04* 0.46 0.00*
 S-I6 mm 0.25 0.09 0.27 0.07 0.14 0.35 0.28 0.06 0.54 0.00*
 S-I8 mm 0.05 0.74 0.19 0.20 −0.07 0.65 0.40 0.01* 0.35 0.01*
 N-T2 mm −0.12 0.43 −0.23 0.13 −0.16 0.30 0.08 0.60 0.03 0.86
 N-T4 mm −0.09 0.56 −0.08 0.61 −0.02 0.88 0.04 0.78 0.12 0.43
 N-T6 mm −0.09 0.54 −0.05 0.72 0.13 0.38 0.18 0.23 0.19 0.20
 N-T8 mm −0.06 0.66 −0.11 0.47 −0.05 0.73 0.15 0.33 −0.05 0.76
Distance from pupillary center to corneal apex
 Lineal distance −0.01 0.94 0.17 0.26 0.03 0.84 0.07 0.63 0.24 0.10
X-axis distance 0.06 0.70 −0.05 0.73 0.29* 0.05 −0.01 0.95 0.21 0.15
Y-axis distance −0.05 0.76 −0.01 0.92 −0.03 0.86 −0.21 0.15 −0.11 0.45
*

Pearson correlation, significant (Sig.) at the 0.05 level. S-I2 mm, S-I4 mm, S-I6 mm, S-I8 mm: superior-inferior corneal thickness differences at 2, 4, 6, and 8 mm diameter concentric circles from the corneal apex, respectively; N-T2 mm, N-T4 mm, N-T6 mm, N-T8 mm: nasal-temporal corneal thickness differences at 2, 4, 6, and 8 mm diameter concentric circles from the corneal apex, respectively; TA3 mm: total corneal astigmatism at 3 mm from the corneal apex; J 0: cylindrical power at 90° or 180° meridian; J 45: cylindrical power at 45° or 135 ° meridian; HOA3 mm: corneal total higher-order aberration at 3 mm pupil diameter; HOA6 mm: corneal total higher-order aberration at 6 mm pupil diameter