Table 2. Measured vs modeled results for change in threshold from a 5.85 mm pupil.
Subject | Stimulus shape and size (μm) | Modeled threshold change | Measured threshold change |
---|---|---|---|
1 | 6.48 circular | 0.73 | 0.74 ( ± 0.07) |
2 | 6.48 circular | 0.73 | 0.85 ( ± 0.14) |
2 | 3.60 square | 1.11 | 1.08 ( ± 0.11) |
1 | 7.92 square | 0.68 | 0.76 ( ± 0.08) |