Skip to main content
. Author manuscript; available in PMC: 2019 Dec 1.
Published in final edited form as: Behav Neurosci. 2018 Oct 25;132(6):561–572. doi: 10.1037/bne0000276

Table 1.

Paired samples t-tests comparing Control to Stress MIST

Measure Control (M±SEM) Stress
(M±SEM)
n t p
Response time 2.87±0.04 2.16±0.04 108 −26.62 0.001
% correct responses 86%±1% 54%±0.1% 108 −36.89 0.001
Stress Rating 13.91±0.54 27.38±0.67 96 16.28 0.001
SCR 0.39±0.04 0.95±0.07 89 8.30 0.001
HR 67.26±1.12 73.94±1.61 69 6.52 0.001

Response time (in seconds) indicates time following math problem presentation to response selection with a button press. HR, Heart Rate; SCR, Skin Conductance Response. Stress ratings were not collected on 12 participants. Thirteen participants had errors in HR data acquisition, and 26 participants had HR with low SNR. Nineteen subjects did not have any SCRs above 0.05 μSiemens. SEM reflects within subject standard error of the mean.