Table 2.

Pulse sequence parameters on magnetic resonance studies.

Sequence Orientation TR/TE/FA
(ms/ms/degree)
FOV
(mm × mm)
Pixel spacing ST/gap (mm/mm)
T1w 2D TSE Coronal 499/13/150 450 × 450 0.87 × 0.87 3/0
T2w 2D TSE Sagittal 4820/98/150 250 × 250 0.78 × 078 3/0
T2w 2D TSE Axial 3970/98/150 250 × 250 0.78 × 0.78 3/0
SE-DW-EPI Axial 2700/83 270 × 230 1.70 × 1.70 4/0
T1w FLASH 3D Axial 9.8/4.76/25 330 × 247 0.59 × 0.59 3/0
T1w FLASH 3D Axial 9.8/4.76/25 330 × 247 0.59 × 0.59 3/0
T1w 2D TSE Sagittal 538/13/150 250 × 250 0.48 × 0.48 3/0
T1w 2D TSE Coronal 538/13/150 250 × 250 0.48 × 0.48 3/0
T1w 2D TSE Axial 450/12/150 270 × 236 0.52 × 0.52 3/0

AT, acquisition time; DW, diffusion weighted; EPI, echo–planar sequence image; FA, flip angle; FLASH, fast low angle shot; FOV, field of view; SE, spin echo; ST, slice thickness; TE, echo time; TF, turbo factor; T1w, T1 weighted; TSE, turbo spin echo; T2w, T2 weighted; TR, repetition time; 2D, two dimensional; 3D, three dimensional.