Table 2.

Diagnostic performance of all acquired quantitative parameters

Index AUC p value Cutoff Sensitivity 95 % CI Specificity 95 % CI
PI 0.540 0.523 1.90 77.8 62.9–88.8 39.5 25.0–55.6
RI 0.642 0.016 0.64 78.7 64.3–89.3 53.3 37.9–68.3
SWVmax 0.867 < 0.0001 3.20 81.5 70.0–90.1 88.1 77.1–95.1
SWVinterm 0.864 < 0.0001 2.58 86.4 75.0–94.0 80.0 67.0–89.6
SWVmin 0.829 < 0.0001 2.10 87.1 76.1–94.3 73.2 59.7–84.2
L/F ratio 0.873 < 0.0001 2.06 92.1 82.4–97.4 74.1 61.0–84.7

PI pulsatility index, RI resistive index, SWV shear wave velocity, SWVmax maximum SWV, SWVinterm intermediate SWV, SWVmin minimum SWV

Cut-off values of SWVmax, SWVinterm, and SWVmin are given in m/s. Sensitivity, specificity, and 95 % confidence intervals in %