Skip to main content
. 2018 Nov 19;18:189. doi: 10.1186/s12935-018-0686-9

Table 2.

Cardiac function data comparison in model group with different suppression time

Group A: within half a year (15 patients) Group B: between half a year and a year (21 patients) Group C: more than a year (28 patients) PAB PAC PBC
EF (%) 73.01 ± 5.18 78.66 ± 5.03 71.39 ± 8.72 0.049 0.274 0.002
PER (EDV/s) 3.97 ± 0.85 4.23 ± 0.44 3.23 ± 0.60 0.438 0.001 0.000
PFR (EDV/s) 3.66 ± 1.04 3.40 ± 0.81 2.38 ± 0.82 0.589 0.000 0.001
MFR/3 (EDV/s) 1.66 ± 0.63 1.66 ± 0.44 1.36 ± 10.29 0.999 0.090 0.050
TTPF (ms) 149.06 ± 46.41 160.95 ± 23.33 172.32 ± 13.75 0.412 0.028 0.331
BMP 80.80 ± 12.09 77.52 ± 7.37 75.44 ± 12.50 0.652 0.286 0.789
Bandwidth 24.11 ± 11.92 25.95 ± 12.59 35.11 ± 18.37 0.869 0.006 0.012
Mean angle (°) 147.52 ± 9.71 144.13 ± 10.97 143.15 ± 17.27 0.751 0.590 0.968
Angle STD (°) 8.64 ± 6.75 8.00 ± 5.59 11.85 ± 10.47 0.972 0.454 0.252
Entropy (%) 27.26 ± 11.86 28.28 ± 8.88 36.92 ± 10.30 0.953 0.013 0.013
SRS 1.20 ± 1.42 0.95 ± 1.32 2.88 ± 2.00 0.898 0.007 0.001
Reduced perfusion ratio (%) 16.67 33.33 67.86

EF ejection fraction, PER peak ejection rate, EDV end-diastolic volume, PFR peak filling rate, MFR/3 mean filling rate over the first third of the end-systolic to end diastolic phase, TTPF time to peak filling from end-systole, BMP beats per minute, STD standard deviation, SRS summed rest score