Table 4.

Assessment of surface contamination by cultural technique (RODAC) and ATP-bioluminescence assay. Comparison of the different sampled surfaces

Sampled surfaces TVC (RODAC) (CFU/plate) ATP-Bioluminescence assay (RLU/100 cm2)
Geometric mean CI 95% Median Range Geometric mean CI 95% Median Range
medical anaesthesia trolley 2.1 1.4–3.0 1 0–14 42.2 24.7–72.3 38 6–510
nurse’s computer touch screen 1.1 1.0–1.4 0 0–3 29.9 17.8–50.2 30 4–480
operating table 1.7 1.2–2.5 0 0–13 35.7 21.6–58.9 31 5–468
vitals monitor 1.4 1.1–1.7 0 0–3 29.6 19.7–44.2 32 5–172
anaesthetist’s computer touch screen 1.6 1.1–2.4 0 0–16 27.2 18.2–40.8 26 5–102
surgical lighting 2.6 1.6–4.1 1 0–41 60.5 37.4–98.1 42.5 13–357
Instrument table 2.4 1.7–3.4 1 0–10 18.4 12.4–27.2 13.5 4–106

CI: Confidence Interval